Corrected Calcium
Corrects total calcium for hypoalbuminemia
Corrected Calcium
9.2mg/dL
Normal (8.8 - 10.4)
Clinical Application
Patients with low albumin may have falsely low total calcium. This formula estimates what the calcium would be if albumin were normal.
Mathematical Metric
Corrected Ca = Measured Ca + 0.8 × (4 - Albumin)
Evidence & Lit
References: Payne RB, et al. Interpretation of serum calcium in patients with abnormal serum proteins.